Bhabha scattering

Feynman diagrams
Annihilation
Scattering

In quantum electrodynamics, Bhabha scattering is the electron-positron scattering process:

There are two leading-order Feynman diagrams contributing to this interaction: an annihilation process and a scattering process. Bhabha scattering is named after the Indian physicist Homi J. Bhabha.

The Bhabha scattering rate is used as a luminosity monitor in electron-positron colliders.

Differential cross section

To leading order, the spin-averaged differential cross section for this process is

where s,t, and u are the Mandelstam variables, is the fine-structure constant, and is the scattering angle.

This cross section is calculated neglecting the electron mass relative to the collision energy and including only the contribution from photon exchange. This is a valid approximation at collision energies small compared to the mass scale of the Z boson, about 91 GeV; at higher energies the contribution from Z boson exchange also becomes important.

Mandelstam variables

In this article, the Mandelstam variables are defined by

        

where the approximations are for the high-energy (relativistic) limit.

Deriving unpolarized cross section

Matrix elements

Both the scattering and annihilation diagrams contribute to the transition matrix element. By letting k and k' represent the four-momentum of the positron, while letting p and p' represent the four-momentum of the electron, and by using Feynman rules one can show the following diagrams give these matrix elements:

Where we use:
are the Gamma matrices,
are the four-component spinors for fermions, while
are the four-component spinors for anti-fermions (see Four spinors).
(scattering) (annihilation)

Notice that there is a relative sign difference between the two diagrams.

Square of matrix element

To calculate the unpolarized cross section, one must average over the spins of the incoming particles (se- and se+ possible values) and sum over the spins of the outgoing particles. That is,

First, calculate :

= (scattering)
(interference)
(interference)
(annihilation)

Scattering term (t-channel)

Magnitude squared of M

    
    
(complex conjugate will flip order)
    
(move terms that depend on same momentum to be next to each other)
    

Sum over spins

Next, we'd like to sum over spins of all four particles. Let s and s' be the spin of the electron and r and r' be the spin of the positron.

    
    
(now use Completeness relations)
    
(now use Trace identities)
    
    

Now that is the exact form, in the case of electrons one is usually interested in energy scales that far exceed the electron mass. Neglecting the electron mass yields the simplified form:

(use the Mandelstam variables in this relativistic limit)

Annihilation term (s-channel)

The process for finding the annihilation term is similar to the above. Since the two diagrams are related by crossing symmetry, and the initial and final state particles are the same, it is sufficient to permute the momenta, yielding

(This is proportional to where is the scattering angle in the center-of-mass frame.)

Solution

Evaluating the interference term along the same lines and adding the three terms yields the final result

Simplifying steps

Completeness relations

The completeness relations for the four-spinors u and v are

where
     (see Feynman slash notation)

Trace identities

Main article: Trace identities

To simplify the trace of the Dirac gamma matrices, one must use trace identities. Three used in this article are:

  1. The Trace of any product of an odd number of 's is zero

Using these two one finds that, for example,

        
(the two middle terms are zero because of (1))
(use identity (2) for the term on the right)
(now use identity (3) for the term on the left)

Uses

Bhabha scattering has been used as a luminosity monitor in a number of e+e collider physics experiments. The accurate measurement of luminosity is necessary for accurate measurements of cross sections.

Small-angle Bhabha scattering was used to measure the luminosity of the 1993 run of the Stanford Large Detector (SLD), with a relative uncertainty of less than 0.5%.[1]

Electron-positron colliders operating in the region of the low-lying hadronic resonances (about 1 GeV to 10 GeV), such as the Beijing Electron Synchrotron (BES) and the Belle and BaBar "B-factory" experiments, use large-angle Bhabha scattering as a luminosity monitor. To achieve the desired precision at the 0.1% level, the experimental measurements must be compared to a theoretical calculation including next-to-leading-order radiative corrections.[2] The high-precision measurement of the total hadronic cross section at these low energies is a crucial input into the theoretical calculation of the anomalous magnetic dipole moment of the muon, which is used to constrain supersymmetry and other models of physics beyond the Standard Model.

References

  1. "a Study of Small Angle Radiative Bhabha Scattering and Measurement of the Lumino".
  2. "[hep-ph/0003268] Large-angle Bhabha scattering and luminosity at flavour factories".
This article is issued from Wikipedia - version of the 6/7/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.